  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP22-1, setting range 0.63-1 A, from Sigma (702200001)

    Next day delivery

    Thermal overload STRP22-1, adjustment range 0.63-1 A from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP22-1 Current adjustment range: 0.63 - 1 A Mounts with: Compatible Sigma contactors Brand: Sigma Item number: 702200001 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP22-10 Adjustment Range 7-10 Amps from Sigma (702200010)

    Next day delivery

    Thermal Overload STRP22-10, 7–10 A Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP22-10 Current adjustment range: 7–10 A Mounts with: Compatible Sigma contactors Brand: Sigma Item number: 702200010 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP22-13, 9–13 A adjustable range, by Sigma (702200013)

    Next day delivery

    Thermal Overload STRP22-13, 9-13 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-13 Current Adjustment Range: 9 - 13 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200013 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connecting and adjusting Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP22-18, 12–18 A adjustable range, from Sigma (702200018)

    Next day delivery

    Thermal Overload STRP22-18, 12-18 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-18 Current Adjustment Range: 12 - 18 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200018 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connecting and adjusting Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP22-2.5 setting range 1-2.5 Amps from Sigma (702200025)

    Next day delivery

    Thermal Overload STRP22-2.5, Adjustment Range 1-2.5 Amps from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-2.5 Current Adjustment Range: 1 - 2.5 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200025 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP22-22 Adjustment Range 16-22 Amps from Sigma (702200022)

    Next day delivery

    Thermal Overload STRP22-22, 16-22 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-22 Current Adjustment Range: 16 - 22 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200022 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connecting and adjusting Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP22-4 setting range 2.5-4 Amps from Sigma (702200004)

    Next day delivery

    Thermal Overload STRP22-4, 2.5–4 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overloading by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP22-4 Current adjustment range: 2.5–4 Amps Compatible with: Compatible Sigma contactors Brand: Sigma Item number: 702200004 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connecting and adjusting Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP22-T, 4–6 A setting range, from Sigma (702200006)

    Next day delivery

    Thermal Overload STRP22-6, 4-6 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-6 Current Adjustment Range: 4 - 6 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200006 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP22-8 adjustment range 5-8 Amps from Sigma (702200008)

    Next day delivery

    Thermal Overload STRP22-8, 5-8 Amp Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP22-8 Current Adjustment Range: 5 - 8 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 702200008 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value listed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connecting and adjusting Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    9.450 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP40-26, 18–26 A setting range, by Sigma (704000026)

    Next day delivery

    Thermal Overload STRP40-26, 18–26 A Adjustment Range from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP40-26 Current adjustment range: 18–26 A Compatible with: Compatible Sigma contactors Brand: Sigma Item number: 704000026 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value indicated on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before wiring and adjustment Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    14.650 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP40-36 Setting Range 25-36 Amps from Sigma (704000036)

    Next day delivery

    Thermal Overload STRP40-36, Adjustment Range 25-36 Amps from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP40-36 Current Adjustment Range: 25 - 36 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 704000036 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    14.650 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP40-40, setting range 28-40 A, from Sigma (704000040)

    Next day delivery

    Thermal overload STRP40-40, setting range 28-40 A from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP40-40 Current setting range: 28 - 40 A Mounts with: Compatible Sigma contactors Brand: Sigma Item number: 704000040 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose a setting range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    14.650 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP85-50 Setting Range 38-50 Amps from Sigma (708500050)

    Next day delivery

    Thermal Overload STRP85-50, Adjustment Range 38-50 Amps from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP85-50 Current Adjustment Range: 38 - 50 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 708500050 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    18.830 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP85-65 adjustment range 45-65 Amps from Sigma (708500065)

    Next day delivery

    Thermal overload STRP85-65, adjustment range 45-65 A from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal protection relay (overload) Model: STRP85-65 Current adjustment range: 45 - 65 A Mounts with: Compatible Sigma contactors Brand: Sigma Item number: 708500065 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    18.830 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal Overload STRP85-75 Setting Range 58-75 Amps from Sigma (708500075)

    Next day delivery

    Thermal Overload STRP85-75, Adjustment Range 58-75 Amps from Sigma. A thermal overload relay that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP85-75 Current Adjustment Range: 58 - 75 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 708500075 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the rated motor current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    18.830 JD

  • أوفر لود حراري STRP85-85 مدى ضبط 63-85 أمبير

    Sigma Thermal overload STRP85-85 setting range 63-85 Amps from Sigma (708500085)

    Next day delivery

    Thermal Overload STRP85-85, Adjustment Range 63-85 Amps from Sigma. A thermal overload protector that protects the motor from overheating and overload by disconnecting the control circuit.Technical Specifications Type: Thermal Protection Relay (Overload) Model: STRP85-85 Current Adjustment Range: 63 - 85 Amps Mounts with: Compatible Sigma contactors Brand: Sigma Item Number: 708500085 Applications Motor overload protection Pump and compressor control panels Industrial control circuits Tips from Amer Shop Set the current to the motor current value printed on its nameplate Choose an adjustment range that covers the motor current Test the Test button after installation 🔧 Usage and Safety Guide Installation: Installed directly below the contactor by a qualified electrician Safety: Disconnect the power before connection and adjustment Important: Do not set the current higher than the motor's rated current Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    18.830 JD

  • قاطع حماية من التسريب الأرضي (ايرث ليكج RCCB) 4 فاز 100 أمبير حساسية 300 ملي أمبير

    Sigma 2-Pole 63A 30mA Residual Current Circuit Breaker (RCCB) from Sigma (320630030)

    Next day delivery

    2-Pole 63A 30mA Residual Current Circuit Breaker (RCCB) from Sigma. A circuit breaker that automatically disconnects the power in the event of a ground fault, protecting people and property.Technical Specifications Type: Residual Current Circuit Breaker (RCCB) Number of Poles: 2 Poles Rated Current: 63 Amps Leakage Sensitivity: 30 Milliamps Installation: 35mm DIN Rail Brand: Sigma Item Number: 320630030 Uses Protecting people from electric shock Protecting bathrooms, kitchens, and wet areas Residential and commercial distribution boards Tips from Amer Shop Choose the amperage based on the cable cross-section and actual load Label each circuit on the board to make maintenance easier Check the tightness of the screws after a period of installation 🔧 Usage and Safety Guide Installation: Installed on a DIN rail inside the electrical panel by a qualified electrician Safety: Disconnect the main power before installation or maintenance and use insulated tools Important: Choose the circuit breaker according to the cable cross-section and load, and do not use a circuit breaker with a higher capacity than the cable Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    24.150 JD

  • قاطع حماية من التسريب الأرضي (ايرث ليكج RCCB) 4 فاز 100 أمبير حساسية 300 ملي أمبير

    Sigma 2-Pole 63A 300mA Residual Current Circuit Breaker (RCCB) from Sigma (320630300)

    Next day delivery

    2-Pole 63A 300mA Residual Current Circuit Breaker (RCCB) from Sigma. A circuit breaker that automatically disconnects the power in the event of a ground fault, protecting people and property.Technical Specifications Type: Residual Current Circuit Breaker (RCCB) Number of Poles: 2 Poles Rated Current: 63 Amps Leakage Sensitivity: 300 mA Installation: 35mm DIN Rail Brand: Sigma Item Number: 320630300 Uses Protection against fires caused by current leakage Main panels in buildings and factories Residential and commercial distribution boards Tips from Amer Shop Choose the amperage based on the cable cross-section and actual load Label each circuit on the panel to make maintenance easier Check the tightness of the screws after a period of installation 🔧 Usage and Safety Guide Installation: Install on a DIN rail inside the electrical panel by a qualified electrician Safety: Disconnect the main power before installation or maintenance and use insulated tools Important: Choose the circuit breaker according to the cable cross-section and load, and do not use a circuit breaker with a higher capacity than the cable Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    24.150 JD

  • قاطع حماية من التسريب الأرضي (ايرث ليكج RCCB) 4 فاز 100 أمبير حساسية 300 ملي أمبير

    Sigma Earth Leakage Circuit Breaker (RCCB) 4 Phase 100 Amp 300 mA Sensitivity from Sigma (341000300)

    Next day delivery

    4-Pole 100A 300mA Residual Current Circuit Breaker (RCCB) from Sigma. A circuit breaker that automatically disconnects the power in the event of a ground fault, protecting people and property.Technical Specifications Type: Residual Current Circuit Breaker (RCCB) Number of Poles: 4 Poles Rated Current: 100 Amps Leakage Sensitivity: 300 mA Installation: 35mm DIN Rail Brand: Sigma Item Number: 341000300 Uses Protection against fires caused by current leakage Main panels in buildings and factories Residential and commercial distribution boards Tips from Amer Shop Choose the amperage based on the cable cross-section and actual load Label each circuit on the panel to make maintenance easier Check the tightness of the screws after a period of installation 🔧 Usage and Safety Guide Installation: Installed on a DIN rail inside the electrical panel by a qualified electrician Safety: Disconnect the main power before installation or maintenance and use insulated tools Important: Choose the circuit breaker according to the cable cross-section and load, and do not use a circuit breaker with a higher capacity than the cable Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    36.650 JD

  • قاطع حماية من التسريب الأرضي (ايرث ليكج RCCB) 4 فاز 100 أمبير حساسية 300 ملي أمبير

    Sigma Sigma 4-Pole 63A 30mA RCCB (340630030)

    Next day delivery

    Residual Current Circuit Breaker (RCCB) 4-Phase 63 Amp 30 mA Sensitivity from Sigma. A circuit breaker that automatically disconnects the power in the event of a ground leak, to protect people and property.Technical Specifications Type: Residual Current Circuit Breaker (RCCB) Number of Poles: 4 Poles Rated Current: 63 Amps Leakage Sensitivity: 30 mA Installation: 35 mm DIN Rail Brand: Sigma Item Number: 340630030 Uses Protecting people from electric shock Protecting bathrooms, kitchens, and wet areas Residential and commercial distribution boards Tips from Amer Shop Choose the amperage based on the cable cross-section and actual load Label each circuit on the board to facilitate maintenance Check the tightness of the screws after a period of installation 🔧 Usage and Safety Guide Installation: Installed on a DIN rail inside the electrical panel by a qualified electrician Safety: Disconnect the main power before installation or maintenance and use insulated tools Important: Choose the circuit breaker according to the cable cross-section and load, and do not use a circuit breaker larger than the cable's capacity Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    26.250 JD

  • قاطع حماية من التسريب الأرضي (ايرث ليكج RCCB) 4 فاز 100 أمبير حساسية 300 ملي أمبير

    Sigma Sigma 4-Pole 63A 300mA RCCB (340630300)

    Next day delivery

    Residual Current Circuit Breaker (RCCB) 4-Phase 63 Amp 300 mA Sensitivity from Sigma. A circuit breaker that automatically disconnects the power in the event of a ground leak, to protect people and property.Technical Specifications Type: Residual Current Circuit Breaker (RCCB) Number of Poles: 4 Poles Rated Current: 63 Amps Leakage Sensitivity: 300 mA Installation: 35 mm DIN Rail Brand: Sigma Item Number: 340630300 Uses Protection against fires caused by current leakage Main panels in buildings and factories Residential and commercial distribution boards Tips from Amer Shop Choose the amperage based on the cable cross-section and actual load Label each circuit on the panel to facilitate maintenance Check the tightness of the screws after a period of installation 🔧 Usage and Safety Guide Installation: Installed on a DIN rail inside the electrical panel by a qualified electrician Safety: Disconnect the main power before installation or maintenance and use insulated tools Important: Choose the circuit breaker according to the cable cross-section and load, and do not use a circuit breaker larger than the cable's capacity Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    32.550 JD

  • قاطع صناعي MCCB 1 فاز 200 أمبير قدرة قطع 36 كيلو أمبير

    Sigma Sigma 1-Phase 100A MCCB, 36kA Breaking Capacity (313610000)

    Next day delivery

    1-Phase 100 Amp MCCB with 36 kA Breaking Capacity from Sigma. A molded case circuit breaker for protecting main lines and heavy loads from overload and short circuits.Technical Specifications Type: Molded Case Circuit Breaker (MCCB) Number of Poles: 1 Pole (1 Phase) Rated Current: 100 Amps Breaking Capacity: 36 kA Brand: Sigma Item Number: 313610000 Uses Protecting main lines in buildings and factories Main and sub-distribution boards Protecting large motors and industrial equipment Tips from Amer Shop Ensure the breaking capacity is suitable for the short-circuit current at your site Use cables with a cross-section suitable for the amperage Tighten the connection terminals well to avoid overheating 🔧 Usage and Safety Guide Installation: Install inside a suitable distribution board by a qualified electrician Safety: Disconnect the main power supply before installation and use protective equipment Important: Do not exceed the breaker's rated current and review the load schedule Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    22.470 JD

  • قاطع صناعي MCCB 1 فاز 200 أمبير قدرة قطع 36 كيلو أمبير

    Sigma Sigma 1-Phase 125A MCCB, 36kA Breaking Capacity (313612500)

    Next day delivery

    1-Phase 125A MCCB with 36kA Breaking Capacity from Sigma. A molded case circuit breaker designed to protect main lines and heavy loads from overloads and short circuits.Technical Specifications Type: Molded Case Circuit Breaker (MCCB) Number of Poles: 1 Pole (1 Phase) Rated Current: 125 Amps Breaking Capacity: 36 kA Brand: Sigma Item Number: 313612500 Applications Protecting main lines in buildings and factories Main and sub-distribution boards Protecting large motors and industrial equipment Tips from Amer Shop Ensure the breaking capacity is suitable for the short-circuit current at your site Use cables with a cross-section suitable for the amperage Tighten the connection terminals properly to prevent overheating 🔧 Usage and Safety Guide Installation: Install inside a suitable distribution board by a qualified electrician Safety: Disconnect the main power supply before installation and use protective equipment Important: Do not exceed the breaker's rated current and review the load schedule Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    22.470 JD

  • قاطع صناعي MCCB 1 فاز 200 أمبير قدرة قطع 36 كيلو أمبير

    Sigma Sigma 1-Phase 160A MCCB, 36kA Breaking Capacity (313616000)

    Next day delivery

    1-Phase 160A MCCB with 36kA breaking capacity from Sigma. A molded case circuit breaker for protecting main lines and heavy loads from overload and short circuits.Technical Specifications Type: Molded Case Circuit Breaker (MCCB) Number of Poles: 1 Pole (1 Phase) Rated Current: 160 Amps Breaking Capacity: 36 kA Brand: Sigma Item Number: 313616000 Applications Protecting main lines in buildings and factories Main and sub-distribution boards Protecting large motors and industrial equipment Tips from Amer Shop Ensure the breaking capacity is suitable for the short-circuit current at your site Use cables with a cross-section suitable for the amperage Tighten the connection terminals well to avoid overheating 🔧 Usage and Safety Guide Installation: Install inside a suitable distribution board by a qualified electrician Safety: Disconnect the main power supply before installation and use protective equipment Important: Do not exceed the breaker's rated current and review the load schedule Order it now from Amer Shop with delivery to all areas of Jordan.

    Next day delivery

    24.990 JD